3RB2016-1PB0
OVERLOAD RELAY 1...4 A FOR MOTOR PROTECTION SIZE S00. CLASS 10 FOR MOUNTING ONTO CONT. MAIN CIRCUIT: SCREW CONNECTION AUX. CIRCUIT: SCREW CONNECTION MANUAL-AUTOMATIC-RESET
REV. COMB. AC3. 3KW/400V AC48V. 50/60 HZ. 3-POLE. SZ S00 SCREW TERMINAL ELECTR. AND MECH. INTERLOCK
SINAMICS G120P POWER MODULE PM230 WITH BUILT IN CL. A FILTER PROTECTION IP55 / UL TYPE12 3AC380-480V +10/-10% 47-63HZ OUTPUT LOW OVERLOAD: 0.55KW FOR 150% 3S.110% 57S.100% 240S AMBIE. TEMP -10 TO+40 DEG C(LO) 460 X 154 X 249 (HXBXT). FSA WITHOUT CONTROL UNIT AND PANEL APPROVED FOR CU230P-2 FIRMWARE-VERSION V4.3.2
SINAMICS G120 POWER MODULE PM250 WITHOUT FILTER POSSIBILITY OF REGENERATION 3AC380-480V +10/-10% 47-63HZ OUTPUT HIGH OVERLOAD: 22KW FOR 200% 3S.150% 57S.100% 240S AMBIENT TEMP -10 TO +50 DEG C OUTPUT LIGHT OVERLOAD: 30KW FOR 150% 3S.110% 57S.100% 240S AMBIENT TEMP -10 TO +40 DEG C 419 X 275 X 204 (HXWXD). FSD PROTECTION IP20 WITHOUT CONTROL UNIT AND BOP
SINAMICS G120 POWER MODULE PM250 WITH BUILT IN CL. A FILTER POSSIBILITY OF REGENERATION 3AC380-480V +10/-10% 47-63HZ OUTPUT HIGH OVERLOAD: 11KW FOR 200% 3S.150% 57S.100% 240S AMBIENT TEMP -10 TO +50 DEG C OUTPUT LIGHT OVERLOAD: 15KW FOR 150% 3S.110% 57S.100% 240S AMBIENT TEMP -10 TO +40 DEG C 334 X 189 X 185 (HXWXD). FSC PROTECTION IP20 WITHOUT CONTROL UNIT AND BOP
SINAMICS G120 POWER MODULE PM240 WITHOUT FILTER WITH BULT IN BRAKING CHOPPER 3AC380-480V +10/-10% 47-63HZ OUTPUT HIGH OVERLOAD: 22KW FOR 200% 3S.150% 57S.100% 240S AMBIENT TEMP -10 TO +50 DEG C OUTPUT LIGHT OVERLOAD: 30KW FOR 150% 3S.110% 57S.100% 240S AMBIENT TEMP -10 TO +40 DEG C 419 X 275 X 204 (HXWXD). FSD PROTECTION IP20 WITHOUT CONTROL UNIT AND BOP
SINAMICS G120 POWER MODULE PM240 WITH BUILT IN CL. A FILTER WITH BULT IN BRAKING CHOPPER 3AC380-480V +10/-10% 47-63HZ OUTPUT HIGH OVERLOAD: 22KW FOR 200% 3S.150% 57S.100% 240S AMBIENT TEMP -10 TO +50 DEG C OUTPUT LIGHT OVERLOAD: 30KW FOR 150% 3S.110% 57S.100% 240S AMBIENT TEMP -10 TO +40 DEG C 512 X 275 X 204 (HXWXD). FSD PROTECTION IP20 WITHOUT CONTROL UNIT AND BOP
SINAMICS G120 POWER MODULE PM240-2 WITHOUT FILTER WITH BUILT IN BRAKING CHOPPER 1/3AC200-240V +10/-10% 47-63HZ OUTPUT HIGH OVERLOAD: 0.75KW FOR 200% 3S.150% 57S.100% 240S AMBIENT TEMP -10 TO +50 DEG C OUTPUT LOW OVERLOAD: 1.1KW FOR 150% 3S.110% 57S.100% 240S AMBIENT TEMP -10 TO +40 DEG C 291 X 100 X 165 (HXWXD). FSB PROTECTION IP20 WITHOUT CONTROL UNIT AND PANEL APPROVED FOR CU FIRMWARE- VERSION V4.6
SINAMICS G120 POWER MODULE PM240-2 WITH BUILT IN CL. A FILTER WITH BUILT IN BRAKING CHOPPER 1/3AC200-240V +10/-10% 47-63HZ OUTPUT HIGH OVERLOAD: 0.75KW FOR 200% 3S.150% 57S.100% 240S AMBIENT TEMP -10 TO +50 DEG C OUTPUT LOW OVERLOAD: 1.1KW FOR 150% 3S.110% 57S.100% 240S AMBIENT TEMP -10 TO +40 DEG C 291 X 100 X 165 (HXWXD). FSB PROTECTION IP20 WITHOUT CONTROL UNIT AND PANEL APPROVED FOR CU FIRMWARE- VERSION V4.6
SINAMICS G120 POWER MODULE PM230 UNFILTERED PROTECTION IP20 3AC380-480V +10/-10% 47-63HZ OUTPUT LOW OVERLOAD: 0.75KW FOR 150% 3S.110% 57S.100% 240S AMBIENT TEMP 0 TO +40 DEG C(LO) 196 X 73 X 165 (HXWXD). FSA WITHOUT CONTROL UNIT AND PANEL APPROVED FOR CU240B/E-2 AND CU230P-2 FIRMWARE-VERSION V4.4 NOTE: PM230 DOES NOT SUPPORT SAFETY
SINAMICS G120 POWER MODULE PM230 WITH BUILT IN CL. A FILTER PROTECTION IP20 3AC380-480V +10/-10% 47-63HZ OUTPUT LOW OVERLOAD: 0.75KW FOR 150% 3S.110% 57S.100% 240S AMBIENT TEMP 0 TO +40 DEG C(LO) 196 X 73 X 165 (HXWXD). FSA WITHOUT CONTROL UNIT AND PANEL APPROVED FOR CU240B/E-2 AND CU230P-2 FIRMWARE-VERSION V4.4 NOTE: PM230 DOES NOT SUPPORT SAFETY
SINAMICS G120 INTELLIGENT OPERATOR PANEL IOP OPTIONAL OPERATOR PANEL FOR SINAMICS G120. G120P. G110D. G120D. G120C. S110. ET200S FC. ET200PRO FC