Elconet

3RP2025-2AP30
SOLID-STATE TIME-DELAY RELAY ON-DELAY 1 CHANGEOVER CONTACT AC/DC 24V. AC 200 TO 240V 0.05 S TO 100H WIDTH 45MM CAGE CLAMP
3RN1010-1BM00
THERMISTOR MOTOR PROTECTION STANDARD EVALUATION UNIT. AUTORESET. 2W.AC230V. SCREW CONNECTION. GALVANIC ISOLATION
3RH1911-1FA31
AUXILIARY SWITCH BLOCK. 31. 3NO+1NC. DIN EN50005. SCREW CONNECTION. F. CONTACTOR RELAYS A. CONTACT. FOR SWITCHING MOTORS. SIZE S00
3RH1253-1AK60
CONTACTOR RELAY. 4 NO+4 NC. NON-DETACHALBLE CONTACT BLOCK. 110 V AC 50 HZ/120 V 60 HZ. SCREW CONNECTION. SIZE S00
3RB2016-2NB0
OVERLOAD RELAY 0.32...1.25 A FOR MOTOR PROTECTION SIZE S00. CLASS 20 FOR MOUNTING ONTO CONT. MAIN CIRCUIT: SCREW CONNECTION AUX. CIRCUIT: SCREW CONNECTION MANUAL-AUTOMATIC-RESET
REV. COMB. AC3. 3KW/400V DC24V 3-POLE. SZ S00 SCREW TERMINAL ELECTR. AND MECH. INTERLOCK WITH INTEGRATED DIODE
SINAMICS G120P POWER MODULE PM230 WITH BUILT IN CL. A FILTER PROTECTION IP55 / UL TYPE12 3AC380-480V +10/-10% 47-63HZ OUTPUT LOW OVERLOAD: 1.5KW FOR 150% 3S.110% 57S.100% 240S AMBIE. TEMP -10 TO+40 DEG C(LO) 460 X 154 X 249 (HXBXT). FSA WITHOUT CONTROL UNIT AND PANEL APPROVED FOR CU230P-2 FIRMWARE-VERSION V4.3.2
SINAMICS G120 POWER MODULE PM250 WITH BUILT IN CL. A FILTER POSSIBILITY OF REGENERATION 3AC380-480V +10/-10% 47-63HZ OUTPUT HIGH OVERLOAD: 45KW FOR 200% 3S.150% 57S.100% 240S AMBIENT TEMP -10 TO +50 DEG C OUTPUT LIGHT OVERLOAD: 55KW FOR 150% 3S.110% 57S.100% 240S AMBIENT TEMP -10 TO +40 DEG C 934 X 350 X 316 (HXWXD). FSF PROTECTION IP20 WITHOUT CONTROL UNIT AND BOP
SINAMICS G120 POWER MODULE PM240 WITHOUT FILTER WITH BULT IN BRAKING CHOPPER 3AC380-480V +10/-10% 47-63HZ OUTPUT HIGH OVERLOAD: 90KW FOR 160% 3S.136% 57S.100% 240S AMBIENT TEMP 0 TO +50 DEG C OUTPUT LIGHT OVERLOAD: 110KW FOR 150% 3S.110% 57S.100% 240S AMBIENT TEMP 0 TO +40 DEG C 634 X 350 X 316 (HXWXD). FSF PROTECTION IP20 WITHOUT CONTROL UNIT AND BOP
SINAMICS G120 POWER MODULE PM240-2 UNFILTERED WITH BUILT IN BRAKING CHOPPER 3AC380-480V +10/-10% 47-63HZ OUTPUT HIGH OVERLOAD: 0.55KW FOR 200% 3S.150% 57S.100% 240S AMBIENT TEMP. -10 TO +50 DEG C OUTPUT LOW OVERLOAD: 0.75KW AT 150% 3S.110% 57S.100% 240S AMBIENT TEMP. -10 TO +40 DEG C 196 X 73 X 165 (HXWXD). FSA PROTECTION IP20 WITHOUT CONTROL UNIT AND PANEL APPROVED FOR CU FIRMWARE-VERSION V4.6
SINAMICS G120 POWER MODULE PM240-2 WITH BUILT IN CL. A FILTER WITH BUILT IN BRAKING CHOPPER 3AC380-480V +10/-10% 47-63HZ OUTPUT HIGH OVERLOAD: 0.55KW FOR 200% 3S.150% 57S.100% 240S AMBIENT TEMP. -10 TO +50 DEG C OUTPUT LOW OVERLOAD: 0.75KW AT 150% 3S.110% 57S.100% 240S AMBIENT TEMP. -10 TO +40 DEG C 196 X 73 X 165 (HXWXD). FSA PROTECTION IP20 WITHOUT CONTROL UNIT AND PANEL APPROVED FOR CU FIRMWARE-VERSION V4.6
SINAMICS G120 POWER MODULE PM230 UNFILTERED PROTECTION IP20 3AC380-480V +10/-10% 47-63HZ OUTPUT LOW OVERLOAD: 5.5KW FOR 150% 3S.110% 57S.100% 240S AMBIENT TEMP 0 TO +40 DEG C(LO) 292 X 100 X 165 (HXWXD). FSB WITHOUT CONTROL UNIT AND PANEL APPROVED FOR CU240B/E-2 AND CU230P-2 FIRMWARE-VERSION V4.4 NOTE: PM230 DOES NOT SUPPORT SAFETY
Se incarca...