SINAMICS G120 POWER MODULE PM240 WITHOUT FILTER WITH BULT IN BRAKING CHOPPER 3AC380-480V +10/-10% 47-63HZ OUTPUT HIGH OVERLOAD: 75KW FOR 200% 3S.150% 57S.100% 240S AMBIENT TEMP -10 TO +50 DEG C OUTPUT LIGHT OVERLOAD: 90KW FOR 150% 3S.110% 57S.100% 240S AMBIENT TEMP -10 TO +40 DEG C 634 X 350 X 316 (HXWXD). FSF PROTECTION IP20 WITHOUT CONTROL UNIT AND BOP
SINAMICS G120 POWER MODULE PM240 WITH BUILT IN CL. A FILTER WITH BULT IN BRAKING CHOPPER 3AC380-480V +10/-10% 47-63HZ OUTPUT HIGH OVERLOAD: 75KW FOR 200% 3S.150% 57S.100% 240S AMBIENT TEMP -10 TO +50 DEG C OUTPUT LIGHT OVERLOAD: 90KW FOR 150% 3S.110% 57S.100% 240S AMBIENT TEMP -10 TO +40 DEG C 934 X 350 X 316 (HXWXD). FSF PROTECTION IP20 WITHOUT CONTROL UNIT AND BOP
SINAMICS G120 POWER MODULE PM240-2 UNFILTERED WITH BUILT IN BRAKING CHOPPER 3AC380-480V +10/-10% 47-63HZ OUTPUT HIGH OVERLOAD: 0.37KW FOR 200% 3S.150% 57S.100% 240S AMBIENT TEMP. -10 TO +50 DEG C OUTPUT LOW OVERLOAD: 0.55KW AT 150% 3S.110% 57S.100% 240S AMBIENT TEMP. -10 TO +40 DEG C 196 X 73 X 165 (HXWXD). FSA PROTECTION IP20 WITHOUT CONTROL UNIT AND PANEL APPROVED FOR CU FIRMWARE-VERSION V4.6
SINAMICS G120 POWER MODULE PM240-2 WITH BUILT IN CL. A FILTER WITH BUILT IN BRAKING CHOPPER 3AC380-480V +10/-10% 47-63HZ OUTPUT HIGH OVERLOAD: 0.37KW FOR 200% 3S.150% 57S.100% 240S AMBIENT TEMP. -10 TO +50 DEG C OUTPUT LOW OVERLOAD: 0.55KW AT 150% 3S.110% 57S.100% 240S AMBIENT TEMP. -10 TO +40 DEG C 196 X 73 X 165 (HXWXD). FSA PROTECTION IP20 WITHOUT CONTROL UNIT AND PANEL APPROVED FOR CU FIRMWARE-VERSION V4.6
SINAMICS G120 POWER MODULE PM230 UNFILTERED PROTECTION IP20 3AC380-480V +10/-10% 47-63HZ OUTPUT LOW OVERLOAD: 4KW FOR 150% 3S.110% 57S.100% 240S AMBIENT TEMP 0 TO +40 DEG C(LO) 292 X 100 X 165 (HXWXD). FSB WITHOUT CONTROL UNIT AND PANEL APPROVED FOR CU240B/E-2 AND CU230P-2 FIRMWARE-VERSION V4.4 NOTE: PM230 DOES NOT SUPPORT SAFETY
SINAMICS G120 POWER MODULE PM230 WITH BUILT IN CL. A FILTER PROTECTION IP20 3AC380-480V +10/-10% 47-63HZ OUTPUT LOW OVERLOAD: 4KW FOR 150% 3S.110% 57S.100% 240S AMBIENT TEMP 0 TO +40 DEG C(LO) 292 X 100 X 165 (HXWXD). FSB WITHOUT CONTROL UNIT AND PANEL APPROVED FOR CU240B/E-2 AND CU230P-2 FIRMWARE-VERSION V4.4 NOTE: PM230 DOES NOT SUPPORT SAFETY
SINAMICS G120 POWER MODULE PM250 WITH BUILT IN CL. A FILTER POSSIBILITY OF REGENERATION 3AC380-480V +10/-10% 47-63HZ OUTPUT HIGH OVERLOAD: 45KW FOR 200% 3S.150% 57S.100% 240S AMBIENT TEMP -10 TO +50 DEG C OUTPUT LIGHT OVERLOAD: 55KW FOR 150% 3S.110% 57S.100% 240S AMBIENT TEMP -10 TO +40 DEG C 934 X 350 X 316 (HXWXD). FSF PROTECTION IP20 WITHOUT CONTROL UNIT AND BOP
SINAMICS G120 POWER MODULE PM240 WITHOUT FILTER WITH BULT IN BRAKING CHOPPER 3AC380-480V +10/-10% 47-63HZ OUTPUT HIGH OVERLOAD: 90KW FOR 160% 3S.136% 57S.100% 240S AMBIENT TEMP 0 TO +50 DEG C OUTPUT LIGHT OVERLOAD: 110KW FOR 150% 3S.110% 57S.100% 240S AMBIENT TEMP 0 TO +40 DEG C 634 X 350 X 316 (HXWXD). FSF PROTECTION IP20 WITHOUT CONTROL UNIT AND BOP
SINAMICS G120 POWER MODULE PM240-2 UNFILTERED WITH BUILT IN BRAKING CHOPPER 3AC380-480V +10/-10% 47-63HZ OUTPUT HIGH OVERLOAD: 0.55KW FOR 200% 3S.150% 57S.100% 240S AMBIENT TEMP. -10 TO +50 DEG C OUTPUT LOW OVERLOAD: 0.75KW AT 150% 3S.110% 57S.100% 240S AMBIENT TEMP. -10 TO +40 DEG C 196 X 73 X 165 (HXWXD). FSA PROTECTION IP20 WITHOUT CONTROL UNIT AND PANEL APPROVED FOR CU FIRMWARE-VERSION V4.6
SINAMICS G120 POWER MODULE PM240-2 WITH BUILT IN CL. A FILTER WITH BUILT IN BRAKING CHOPPER 3AC380-480V +10/-10% 47-63HZ OUTPUT HIGH OVERLOAD: 0.55KW FOR 200% 3S.150% 57S.100% 240S AMBIENT TEMP. -10 TO +50 DEG C OUTPUT LOW OVERLOAD: 0.75KW AT 150% 3S.110% 57S.100% 240S AMBIENT TEMP. -10 TO +40 DEG C 196 X 73 X 165 (HXWXD). FSA PROTECTION IP20 WITHOUT CONTROL UNIT AND PANEL APPROVED FOR CU FIRMWARE-VERSION V4.6
SINAMICS G120 POWER MODULE PM230 UNFILTERED PROTECTION IP20 3AC380-480V +10/-10% 47-63HZ OUTPUT LOW OVERLOAD: 5.5KW FOR 150% 3S.110% 57S.100% 240S AMBIENT TEMP 0 TO +40 DEG C(LO) 292 X 100 X 165 (HXWXD). FSB WITHOUT CONTROL UNIT AND PANEL APPROVED FOR CU240B/E-2 AND CU230P-2 FIRMWARE-VERSION V4.4 NOTE: PM230 DOES NOT SUPPORT SAFETY
SINAMICS G120 POWER MODULE PM230 WITH BUILT IN CL. A FILTER PROTECTION IP20 3AC380-480V +10/-10% 47-63HZ OUTPUT LOW OVERLOAD: 5.5KW FOR 150% 3S.110% 57S.100% 240S AMBIENT TEMP 0 TO +40 DEG C(LO) 292 X 100 X 165 (HXWXD). FSB WITHOUT CONTROL UNIT AND PANEL APPROVED FOR CU240B/E-2 AND CU230P-2 FIRMWARE-VERSION V4.4 NOTE: PM230 DOES NOT SUPPORT SAFETY