Siemens

MICROMASTER 420 WITH BUILT IN CLASS A FILTER 1AC 200-240V +10/-10% 47-63HZ CONSTANT TORQUE POWER 0.37 KW OVERLOAD 150% FOR 60S VARIABLE TORQUE POWER 0.37 KW 173 X 73 X 149 (H X W X D) PROTECTION IP20 AMBIENT TEMP -10 TO +50 DEG C W/O AOP/BOP
MICROMASTER 440 WITHOUT FILTER 3AC 380-480 V +10/-10% 47-63 HZ CONSTANT TORQUE POWER 0.75 KW OVERLOAD 150% 60 S. 200% 3 S SQUARED TORQUE POWER 0.75 KW 173 X 73 X 149 (H X W X D) PROTECTION IP20 AMBIENT TEMP. -10 TO +50 DEG. C WITHOUT AOP/BOP
MICROMASTER 440 WITHOUT FILTER 1/3AC 200-240V +10/-10% 47-63HZ CONSTANT TORQUE POWER 0.37 KW OVERLOAD 150% 60 S. 200% 3 S SQUARED TORQUE POWER 0.37 KW 173 X 73 X 149 (H X W X D) PROTECTION IP20 AMBIENT TEMP. -10 TO +50 DEG. C WITHOUT AOP/BOP
MICROMASTER 440 WITH BUILT-IN CLASS A FILTER 3AC 380-480 V +10/-10% 47-63 HZ CONSTANT TORQUE POWER 4 KW OVERLOAD 150% 60 S. 200% 3 S SQUARED TORQUE POWER 4 KW 202 X 149 X 172 (H X W X D) PROTECTION IP20 AMBIENT TEMP. -10 TO +50 DEG. C WITHOUT AOP/BOP
MICROMASTER 440 WITH BUILT-IN CLASS A FILTER 1AC 200-240 V +10/-10% 47-63 HZ CONSTANT TORQUE POWER 0.37 KW OVERLOAD 150% 60 S. 200% 3 S SQUARED TORQUE POWER 0.37 KW 173 X 73 X 149 (H X W X D) PROTECTION IP20 AMBIENT TEMP. -10 TO +50 DEG. C WITHOUT AOP/BOP
MICROMASTER 4 ENCODER OPTION MODULE TTL DIFFERENTIAL / HTL INCREMENTAL 300 KHZ MAX.. 5 V OR 24 V. 3W ENCA. ENCB. ENCZ // ENC-REC
SINAMICS G120P POWER MODULE PM230 WITH BUILT IN CL. B FILTER PROTECTION IP55 / UL TYPE12 3AC380-480V +10/-10% 47-63HZ OUTPUT LOW OVERLOAD: 0.55KW FOR 150% 3S.110% 57S.100% 240S AMBIE. TEMP -10 TO+40 DEG C(LO) 460 X 154 X 249 (HXBXT). FSA WITHOUT CONTROL UNIT AND PANEL APPROVED FOR CU230P-2 FIRMWARE-VERSION V4.3.2
SINAMICS G120 POWER MODULE PM250 WITHOUT FILTER POSSIBILITY OF REGENERATION 3AC380-480V +10/-10% 47-63HZ OUTPUT HIGH OVERLOAD: 30KW FOR 200% 3S.150% 57S.100% 240S AMBIENT TEMP -10 TO +50 DEG C OUTPUT LIGHT OVERLOAD: 37KW FOR 150% 3S.110% 57S.100% 240S AMBIENT TEMP -10 TO +40 DEG C 499 X 275 X 204 (HXWXD). FSE PROTECTION IP20 WITHOUT CONTROL UNIT AND BOP
SINAMICS G120 POWER MODULE PM250 WITH BUILT IN CL. A FILTER POSSIBILITY OF REGENERATION 3AC380-480V +10/-10% 47-63HZ OUTPUT HIGH OVERLOAD: 15KW FOR 200% 3S.150% 57S.100% 240S AMBIENT TEMP -10 TO +50 DEG C OUTPUT LIGHT OVERLOAD: 18.5KW FOR 150% 3S.110% 57S.100% 240S AMBIENT TEMP -10 TO +40 DEG C 512 X 275 X 204 (HXWXD). FSD PROTECTION IP20 WITHOUT CONTROL UNIT AND BOP
SINAMICS G120 POWER MODULE PM240 WITHOUT FILTER WITH BULT IN BRAKING CHOPPER 3AC380-480V +10/-10% 47-63HZ OUTPUT HIGH OVERLOAD: 30KW FOR 200% 3S.150% 57S.100% 240S AMBIENT TEMP -10 TO +50 DEG C OUTPUT LIGHT OVERLOAD: 37KW FOR 150% 3S.110% 57S.100% 240S AMBIENT TEMP -10 TO +40 DEG C 497 X 275 X 204 (HXWXD). FSE PROTECTION IP20 WITHOUT CONTROL UNIT AND BOP
SINAMICS G120 POWER MODULE PM240 WITH BUILT IN CL. A FILTER WITH BULT IN BRAKING CHOPPER 3AC380-480V +10/-10% 47-63HZ OUTPUT HIGH OVERLOAD: 30KW FOR 200% 3S.150% 57S.100% 240S AMBIENT TEMP -10 TO +50 DEG C OUTPUT LIGHT OVERLOAD: 37KW FOR 150% 3S.110% 57S.100% 240S AMBIENT TEMP -10 TO +40 DEG C 635 X 275 X 204 (HXWXD). FSE PROTECTION IP20 WITHOUT CONTROL UNIT AND BOP
SINAMICS G120 POWER MODULE PM240-2 WITHOUT FILTER WITH BUILT IN BRAKING CHOPPER 1/3AC200-240V +10/-10% 47-63HZ OUTPUT HIGH OVERLOAD: 1.1KW FOR 200% 3S.150% 57S.100% 240S AMBIENT TEMP -10 TO +50 DEG C OUTPUT LOW OVERLOAD: 1.5KW FOR 150% 3S.110% 57S.100% 240S AMBIENT TEMP -10 TO +40 DEG C 291 X 100 X 165 (HXWXD). FSB PROTECTION IP20 WITHOUT CONTROL UNIT AND PANEL APPROVED FOR CU FIRMWARE- VERSION V4.6
Loading...
Back to top